Specifications

General Measurement
Number of inputs: 3

Update rate: Up to 4 rdg/s on display; up to 18 rdg/s with IEEE-488 interface

Measurement modes: DC, RMS, peak

Probe compatibility: Standard, multi-axis, and custom probes

Probe features: Linearity Correction, Temperature Correction, Auto Probe Zero

Measurement features: Autorange, Max Hold, Relative Mode, Filter, Vector Magnitude, Differential Reading

Probe connector: 15-pin D style
DC Measurement
Probe Type Ranges 5¾-digits
with filter
4¾-digits
without filter
HST Probe
300 kG 0.001 kG 0.01 kG
30 kG 0.0001 kG 0.001 kG
3 kG 0.00001 kG 0.0001 kG
300 G 0.001 G 0.01 G
HSE Probe
30 kG 0.0001 kG 0.001 kG
3 kG 0.00001 kG 0.0001 kG
300 G 0.001 G 0.01 G
30 G 0.0001 G 0.001 G
UHS Probe (Discontinued)
30 G 0.0001 G 0.001 G
3 G 0.00001 G 0.0001 G
300 mG 0.001 mG 0.01 mG

DC accuracy: ±0.10% of reading ±0.005% of range
DC temperature coefficient: ±0.05% of reading ±0.003% of range per ºC
AC RMS & Peak Measurement
AC display resolution: 4¾ digits
Probe Type Ranges RMS Resolution Peak Resolution
HST Probe
300 kG 0.01 kG 0.01 kG
30 kG 0.001 kG 0.001 kG
3 kG 0.0001 kG 0.0001 kG
300 G 0.01 G ×
HSE Probe
30 kG 0.001 kG 0.001 kG
3 kG 0.0001 kG 0.0001 kG
300 G 0.01 G 0.01 G
30 G 0.001 G ×
UHS Probe (Discontinued)
30 G 0.001 G 0.001 G
3 G 0.0001 G 0.0001 G
300 mG 0.01 mG ×

AC frequency range:
10 Hz to 400 Hz

AC RMS accuracy:
±2% of reading (50 Hz to 60 Hz)

AC RMS frequency response:
0 to -3.5% of reading (10 Hz to 400 Hz)
(All AC RMS specifications for sinusoidal input >1% of range)

AC peak accuracy: ±5% typical

AC peak speed:
5 ms for single peak
Front Panel
Display type: 4-line × 20-character, vacuum fluorescent

Display resolution:
Up to ±5¾ digits

Display update rate:
4 rdg/s with Vector off, 3 rdg/s with Vector on

Display units:
Gauss (G), Telsa (T)

Units multipliers:
µ, m k

Annunciators:
RMS: AC input signal, DC: DC input signal, MAX: Max Hold value, s: Relative reading, R: Remote operation,  ?:Alarm on

Keypad: 25 full travel keys

Front panel features: Intutive operation, display prompts, front panel lockout, brightness control
Interfaces
RS-232C capabilities
Baud: 300, 1200, 9600
Connector: RJ-11 configuration
Update rate: Up to 14 rdg/s at 9600 baud
IEEE-488 capabilities
Complies with IEEE-488.2 SH1, AH1, SR1, RL1, PP0, DC1, DT0, C0, E1
Update rate: 18 rdg/s with Vector off, 14 rdg/s with Vector on
Alarm
Settings: High and low setpoint, Inside/Outside, Audible
Actuators: Display annuciator, beeper
Monitor analog output (3)
Configuration: Real time analog voltage output
Scale: ±3 V = ±FS on selected range
Frequency response: DC to 400 Hz
Accuracy: Probe dependent
Minimum load resistance: 1 kO (short circuit protected)
Connector: BNC
Corrected analog output (1)
Configuration: Voltage output generated by DAC
Range: ±3 V; ±10 V for the Model 460-10
Scale: User-defined
Resolution: 0.366 mV of ±3 V
Update rate: Same as field measurement
Accuracy: ±0.1% full scale in addition to measurement error
Minimum load resistance: 1 kO (short circuit protected)
Connector: BNC
General
Ambient temperature: 15 to 35 ºC at rated accuracy. 5 to 40 ºC with reduced accuracy

Power requirement:
100, 120, 220, 240 VAC (+5%, -10%), 50 or 60 Hz, 40 VA

Size: 432 mm W × 89 mm H × 368 mm D (17 in × 3.5 in × 14.5 in), full rack

Weight: 7.5 kg (16.5 lb)